Christopher Michael Fredenburg
- Listed as
- architect, authorized agent-others, contractor, designer, engineer
- Firm
- Aquamatic Fire Protection
- Based in
- Pittsburg
- On San Francisco permits
- Apr 2000 to Dec 2025
531 permits since 2000 (contractor on 527 permits, engineer on 9 permits, designer on 7 permits, architect on 4 permits, authorized agent-others on 3 permits): 337 completed, 7 in progress, 92 never finaled, 95 expired or cancelled.
This is the city’s permit record, not a license check: the role and the number come from what was written on each permit (the number spelled one way). It does not show whether the license is current. Their ranked record as a contractor is on their contractor page. How to read these records
Most recent permits
Showing the 100 most recent of 531.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Dec 23, 2025 | Completed final sign-off Jan 2026 | 88 Stevenson St | Aquamatic Fire Protection | relocate (8) pendent fire sprinklers for new wall layout at basement level. ref bldg permit 202509054708.Details
relocate (8) pendent fire sprinklers for new wall layout at basement level. ref bldg permit 202509054708. | $8,200 |
| Dec 22, 2025 | Completed final sign-off Jan 2026 | 131 Steuart St | Aquamatic Fire Protection | 1/f: as built for permit #202508122838. no underground work.Details
1/f: as built for permit #202508122838. no underground work. | |
| Nov 6, 2025 | Completed final sign-off Jun 2026 | 172 06th St | Aquamatic Fire Protection | 1st floor: relocate and replace (6) pendent fire sprinklers for tenant improvement. no underground work. reference t.i. permit #202407317631Details
1st floor: relocate and replace (6) pendent fire sprinklers for tenant improvement. no underground work. reference t.i. permit #202407317631 | $10,700 |
| Oct 21, 2025 | Completed final sign-off Mar 2026 | 3821 Noriega St | Aquamatic Fire Protection | tie into new sfwd connection and install approx 10 ft of underground to the bldg. ref ti #202508203491. install new riser, backflow & fire sprinkler system in e) bldgDetails
tie into new sfwd connection and install approx 10 ft of underground to the bldg. ref ti #202508203491. install new riser, backflow & fire sprinkler system in e) bldg | $30,100 |
| Oct 10, 2025 | Completed final sign-off May 2026 | 642 Harrison St | Aquamatic Fire Protection | relocate and replace (5) add (17) pendent fire sprinklers as part of defciency work. not associated with any building permit. no under ground work.Details
relocate and replace (5) add (17) pendent fire sprinklers as part of defciency work. not associated with any building permit. no under ground work. | $14,100 |
| Oct 6, 2025 | Completed final sign-off Nov 2025 | 465 California St | Aquamatic Fire Protection | 14/fl-fire sprinker only ti 202508253785- no underground work, relocate & replace(add) 51 fire sprinklers for t.i.Details
14/fl-fire sprinker only ti 202508253785- no underground work, relocate & replace(add) 51 fire sprinklers for t.i. | $11,400 |
| Oct 6, 2025 | Completed final sign-off Dec 2025 | 85 02nd St | Aquamatic Fire Protection | 7/fl-relocate amd replace (2) , add (1) , plug (2) pendent fire sprinklers. no underground work. ref ti 202509084762Details
7/fl-relocate amd replace (2) , add (1) , plug (2) pendent fire sprinklers. no underground work. ref ti 202509084762 | $5,900 |
| Aug 12, 2025 | Completed final sign-off Jan 2026 | 131 Steuart St | Aquamatic Fire Protection | 1/fl- relocate and repalce swap in place (9) fire sprinkler for ti 202506128549. no underground workDetails
1/fl- relocate and repalce swap in place (9) fire sprinkler for ti 202506128549. no underground work | $8,500 |
| Jul 21, 2025 | Completed final sign-off Oct 2025 | 1100 Van Ness Av | Aquamatic Fire Protection | ref ti 202505065851- ste. 1045- relocate and replace (14) /add (2) pendent fire sprinklers for ti. no underground work.Details
ref ti 202505065851- ste. 1045- relocate and replace (14) /add (2) pendent fire sprinklers for ti. no underground work. | $9,500 |
| Jul 14, 2025 | Completed final sign-off Oct 2025 | 1155 04th St | Aquamatic Fire Protection | 1st fl, ste 1b relocate and replace/add (24) fire sprinklers, for ti. no underground work. ref pa 202409050160Details
1st fl, ste 1b relocate and replace/add (24) fire sprinklers, for ti. no underground work. ref pa 202409050160 | $12,000 |
| Jul 14, 2025 | Completed final sign-off Aug 2025 | 350 Masonic Av | Aquamatic Fire Protection | relocated and replace/add (16) fire sprinklers for ti 202506309738. no underground work.Details
relocated and replace/add (16) fire sprinklers for ti 202506309738. no underground work. | $9,300 |
| May 19, 2025 | Completed final sign-off May 2025 | 2533 Baker St | Aquamatic Fire Protection | as built for pa #2013-0305-1492Details
as built for pa #2013-0305-1492 | |
| Apr 15, 2025 | In progress issued Jun 2025 | 737 Folsom St | Aquamatic Fire Protection | add a new automatic fire sprinkler system with a new fire pump on 1st floor. install heads in floors 2-9 in corridors and install 1 sprinkler is each unit entrance for future installation.existing sprinkler system on the fist floor to remainDetails
add a new automatic fire sprinkler system with a new fire pump on 1st floor. install heads in floors 2-9 in corridors and install 1 sprinkler is each unit entrance for future installation.existing sprinkler system on the fist floor to remain | $500,000 |
| Apr 10, 2025 | Completed final sign-off Nov 2025 | 2533 Baker St | Aquamatic Fire Protection | to obtain a final inspection for work approved under pa # 2013-0305-1492. all work completeDetails
to obtain a final inspection for work approved under pa # 2013-0305-1492. all work complete | |
| Mar 4, 2025 | Completed final sign-off Jan 2026 | 241 06th St | Aquamatic Fire Protection | plug 2 sidewall sprinklers and remove pipe in elevator pit. plug 4 pendent sprinklers and reroute piping in the elevator machine room. work being performed per fire department requirements. no underground work. work is voluntary & not associated with a building permit.Details
plug 2 sidewall sprinklers and remove pipe in elevator pit. plug 4 pendent sprinklers and reroute piping in the elevator machine room. work being performed per fire department requirements. no underground work. work is voluntary & not associated with a building permit. | $6,900 |
| Jan 6, 2025 | Completed final sign-off Apr 2025 | 220 04th St | Aquamatic Fire Protection | 1/f: relocate and replace 18 fire sprinklers for tenant improvement. no underground work. reference ti#2023-1221-2914Details
1/f: relocate and replace 18 fire sprinklers for tenant improvement. no underground work. reference ti#2023-1221-2914 | $13,800 |
| Dec 11, 2024 | Completed final sign-off Feb 2026 | 3270 18th St | Aquamatic Fire Protection | install 6 inch x6 foot one piece stainless steel in-building riser ug stub form the interior fire sprinkler riser location to 5 feet outside of bdlg footprint. pa#: 202212148290 addendum 3Details
install 6 inch x6 foot one piece stainless steel in-building riser ug stub form the interior fire sprinkler riser location to 5 feet outside of bdlg footprint. pa#: 202212148290 addendum 3 | $5,000 |
| Nov 26, 2024 | Completed final sign-off Jan 2025 | 790 Pennsylvania Av | Aquamatic Fire Protection | 1st floor. add (3) upright fire sprinklers fornew full height wall. no underground work. ref#: 202410223446. add (1) sidewall sprinkler for existing roll up door.Details
1st floor. add (3) upright fire sprinklers fornew full height wall. no underground work. ref#: 202410223446. add (1) sidewall sprinkler for existing roll up door. | $8,300 |
| Oct 21, 2024 | In progress issued Oct 2024 | 241 06th St | Aquamatic Fire Protection | 2nd floor through 8th floor. relocate and replace (28) fire sprinklers for tenant improvement. no underground work ref t.i.#: 201601298422Details
2nd floor through 8th floor. relocate and replace (28) fire sprinklers for tenant improvement. no underground work ref t.i.#: 201601298422 | $8,700 |
| Sep 13, 2024 | In progress issued Sep 2024 | 2745 19th St | Aquamatic Fire Protection | revision to 202409060239. no underground work. ref 202407257227Details
revision to 202409060239. no underground work. ref 202407257227 | |
| Sep 6, 2024 | In progress issued Sep 2024 | 1160 Mission St | Aquamatic Fire Protection | as built for pa# 202408138545.Details
as built for pa# 202408138545. | |
| Sep 6, 2024 | Completed final sign-off Dec 2024 | 2745 19th St | Aquamatic Fire Protection | ref 202407257227-relocate and replace/add (14) fire sprinklers for ti. no under ground workDetails
ref 202407257227-relocate and replace/add (14) fire sprinklers for ti. no under ground work | $6,300 |
| Sep 6, 2024 | Completed final sign-off Mar 2026 | 241 06th St | Aquamatic Fire Protection | replace (e) fire pump, jockey pump and controller with (n) to the same specs as the one being repalced. not associated with a building permit. no underground work.Details
replace (e) fire pump, jockey pump and controller with (n) to the same specs as the one being repalced. not associated with a building permit. no underground work. | $60,000 |
| Aug 13, 2024 | Completed final sign-off Sep 2024 | 1160 Mission St | Aquamatic Fire Protection | add 3 plug 1 upright fire sprinklers for ti. no underground work ref pa 202406144545Details
add 3 plug 1 upright fire sprinklers for ti. no underground work ref pa 202406144545 | $6,300 |
| Jul 26, 2024 | In progress issued Jul 2024 | 206 Sansome St | Aquamatic Fire Protection | 1st floor: add 37 fire sprinklers for voluntary owner upgrade. no underground work. not associated with any building permit.Details
1st floor: add 37 fire sprinklers for voluntary owner upgrade. no underground work. not associated with any building permit. | $2,200 |
| Jun 17, 2024 | Completed final sign-off Jul 2024 | 2645 Ocean Av | Aquamatic Fire Protection | #105: as-built for pa# 202406043654. fire onlyDetails
#105: as-built for pa# 202406043654. fire only | |
| Jun 4, 2024 | In progress issued Jun 2024 | 2645 Ocean Av | Aquamatic Fire Protection | ste #105: relocate and replace (3), add (1) pendent sprinkler sprinkler for tenant improvement. no underground work. ref ti# 202402296785Details
ste #105: relocate and replace (3), add (1) pendent sprinkler sprinkler for tenant improvement. no underground work. ref ti# 202402296785 | $6,700 |
| Apr 24, 2024 | Completed final sign-off Jul 2025 | 251 Rhode Island St | Aquamatic Fire Protection | ref 202312152587- 1st/f & 2nd/f to relocate and replace (18) pendent fire sprinklers for ti . no underground work.Details
ref 202312152587- 1st/f & 2nd/f to relocate and replace (18) pendent fire sprinklers for ti . no underground work. | $12,200 |
| Mar 19, 2024 | Completed final sign-off May 2024 | 220 Jackson St | Aquamatic Fire Protection | unit#350: add/relocate and replace 65 fire sprinklers fo t.i. no under ground work. ref pa#202402226337Details
unit#350: add/relocate and replace 65 fire sprinklers fo t.i. no under ground work. ref pa#202402226337 | $13,800 |
| Jan 10, 2024 | Completed final sign-off Apr 2024 | 206 Sansome St | Aquamatic Fire Protection | add (82) fire sprinklers for voluntary owner upgrade. no underground work, not associated with any bldg permit. on 10/f, 12/f-13/fDetails
add (82) fire sprinklers for voluntary owner upgrade. no underground work, not associated with any bldg permit. on 10/f, 12/f-13/f | $43,600 |
| Dec 11, 2023 | Completed final sign-off Feb 2024 | 1160 Mission St | Aquamatic Fire Protection | garage lvl: relocate and replace/ add 3 fire sprinklers for ti, no underground work, ref pa# 202308104182.Details
garage lvl: relocate and replace/ add 3 fire sprinklers for ti, no underground work, ref pa# 202308104182. | $8,800 |
| Dec 11, 2023 | Completed final sign-off Apr 2024 | 2240 Market St | Aquamatic Fire Protection | relocate and replace/ add 16 fire sprinklers for ti, no underground work, ref pa# 202212138181.Details
relocate and replace/ add 16 fire sprinklers for ti, no underground work, ref pa# 202212138181. | $10,100 |
| Oct 16, 2023 | In progress issued Oct 2023 | 315 Pacific Av | Aquamatic Fire Protection | 1-3/f: relocated and replace/ add 61 fire sprinklers for ti. no underground work. ref t.i. pa# 202308305583.Details
1-3/f: relocated and replace/ add 61 fire sprinklers for ti. no underground work. ref t.i. pa# 202308305583. | $20,900 |
| Mar 17, 2023 | Completed final sign-off Apr 2023 | 140 Geary St | Aquamatic Fire Protection | 3/f: relocate and replace 48/add 1 fire sprinlers to return space to shell condition. add branchline restraints in area of work. no underground work. ref ti. pa# 202303033046Details
3/f: relocate and replace 48/add 1 fire sprinlers to return space to shell condition. add branchline restraints in area of work. no underground work. ref ti. pa# 202303033046 | $14,000 |
| Feb 6, 2023 | Completed final sign-off Feb 2023 | 260 Townsend St | Aquamatic Fire Protection | as-built for fire sprinkler pa# 202203291108Details
as-built for fire sprinkler pa# 202203291108 | |
| Dec 29, 2022 | Completed final sign-off Feb 2023 | 1550 Bryant St | Aquamatic Fire Protection | 6/f: add 8 pendent fire sprinklers for new phone booths. no underground work. ref pa# 2022-1017-4517.Details
6/f: add 8 pendent fire sprinklers for new phone booths. no underground work. ref pa# 2022-1017-4517. | $12,600 |
| Nov 14, 2022 | Never finaled issued Nov 2022, no final | 950 Tennessee St | Aquamatic Fire Protection | basement: modify 106 sidewall sprinklers to make them more recessed and less likely of possible damage at the request of the building owner. no underground work.Details
basement: modify 106 sidewall sprinklers to make them more recessed and less likely of possible damage at the request of the building owner. no underground work. | $9,400 |
| Oct 19, 2022 | Completed final sign-off Dec 2023 | 552 Capp St | Aquamatic Fire Protection | install new nfpa 13 fire sprinkler system in existing building (60 heads); underground portions on separate permit. ref pa 201912300968Details
install new nfpa 13 fire sprinkler system in existing building (60 heads); underground portions on separate permit. ref pa 201912300968 | $44,900 |
| Oct 11, 2022 | Completed final sign-off Oct 2022 | 1550 Bryant St | Aquamatic Fire Protection | 8/f: as built for fire sprinkler permit 202209082095Details
8/f: as built for fire sprinkler permit 202209082095 | |
| Sep 30, 2022 | Never finaled issued Sep 2022, no final | 275 Sacramento St | Aquamatic Fire Protection | plug (1) pdendent fire sprinkler, no underground workDetails
plug (1) pdendent fire sprinkler, no underground work | $5,900 |
| Sep 16, 2022 | Completed final sign-off May 2023 | 1566 48th Av | Aquamatic Fire Protection | provide new sprinkler system throughout 3 story bldg starting @ 2 domestic water line in garage.reference bpa#201812117970.Details
provide new sprinkler system throughout 3 story bldg starting @ 2 domestic water line in garage.reference bpa#201812117970. | $2,800 |
| Sep 13, 2022 | Completed final sign-off Jan 2023 | 733 Front St | Aquamatic Fire Protection | relocate and replace (4) pendent fire sprinklers for tenant improvement. no underground work. ref t.i. #2022-0517-4386.Details
relocate and replace (4) pendent fire sprinklers for tenant improvement. no underground work. ref t.i. #2022-0517-4386. | $6,900 |
| Sep 8, 2022 | Completed final sign-off Oct 2022 | 1550 Bryant St | Aquamatic Fire Protection | 8th fl: add 10 fire sprinklers. no underground work. ref pa# 202208190889.Details
8th fl: add 10 fire sprinklers. no underground work. ref pa# 202208190889. | $7,500 |
| Sep 8, 2022 | Completed final sign-off Feb 2023 | 1550 Bryant St | Aquamatic Fire Protection | 2nd fl: relocate and replace 4/ add 2 fire sprinklers for tenant improvement. no underground work. ref pa# 202208180779.Details
2nd fl: relocate and replace 4/ add 2 fire sprinklers for tenant improvement. no underground work. ref pa# 202208180779. | $7,500 |
| Aug 19, 2022 | Never finaled filed Aug 2022, never issued | 301 Toland St | Aquamatic Fire Protection | fire sprinklers: relocate and replace 4, add 41 and plug 1. no u/g. t.i. pa202208180778Details
fire sprinklers: relocate and replace 4, add 41 and plug 1. no u/g. t.i. pa202208180778 | $22,300 |
| Aug 19, 2022 | Completed final sign-off Sep 2022 | 1550 Bryant St | Aquamatic Fire Protection | 2nd fl: add 10 fire sprinklers. no underground work. ref pa# 202206176601.Details
2nd fl: add 10 fire sprinklers. no underground work. ref pa# 202206176601. | $7,500 |
| Jul 8, 2022 | Completed final sign-off Sep 2023 | 175 Scotia Av | Aquamatic Fire Protection | add new automatic fire sprinkler system including underground for (e) building.Details
add new automatic fire sprinkler system including underground for (e) building. | $80,000 |
| Jun 29, 2022 | Completed final sign-off Aug 2022 | 3101 Moraga St | Aquamatic Fire Protection | add 8 upright sprinkler heads per nfpa 13 (2016). ref 202203280975 on 4th floor.Details
add 8 upright sprinkler heads per nfpa 13 (2016). ref 202203280975 on 4th floor. | $8,000 |
| Mar 29, 2022 | Completed final sign-off Feb 2023 | 260 Townsend St | Aquamatic Fire Protection | 4/f: relocate/replace (55) fire sprinklers for t.i. no underground work.Details
4/f: relocate/replace (55) fire sprinklers for t.i. no underground work. | $16,600 |
| Dec 20, 2021 | Completed final sign-off Feb 2022 | 170 Capp St | Aquamatic Fire Protection | 3rd fl: relocate and replace 2. add 5 upright sprinkers. no underground work. ref 202110120250Details
3rd fl: relocate and replace 2. add 5 upright sprinkers. no underground work. ref 202110120250 | $6,000 |
| Dec 20, 2021 | Completed final sign-off May 2023 | 1566 48th Av | Aquamatic Fire Protection | fully sprinkle all levels per nfpa 13r for remodel of (e) 2-story single family home with a ground & 2nd floor extensions & a one story addition above 2nd floor 3 stories, 2 residential units, 1 adu unit total.Details
fully sprinkle all levels per nfpa 13r for remodel of (e) 2-story single family home with a ground & 2nd floor extensions & a one story addition above 2nd floor 3 stories, 2 residential units, 1 adu unit total. | $28,000 |
| Dec 20, 2021 | Completed final sign-off Mar 2022 | 600 Townsend St | Aquamatic Fire Protection | as built for permit #202108236924Details
as built for permit #202108236924 | |
| Dec 6, 2021 | Completed final sign-off Jun 2022 | 801 Howard St | Aquamatic Fire Protection | floors 2-9: voluntarily installation of additional fire sprinklers inside the entry's of residential units. 161 fire sprinklers.Details
floors 2-9: voluntarily installation of additional fire sprinklers inside the entry's of residential units. 161 fire sprinklers. | $115,000 |
| Oct 15, 2021 | Completed final sign-off Jan 2025 | 1023 Mission St | Aquamatic Fire Protection | revise fire sprinlker plans already approved per architect revisions. ref 202103247161 resubmittal to 202105200733. no underground work. relocate and replace (16) upright sprinklers with new pendent sprinklers on 1/f and basement.Details
revise fire sprinlker plans already approved per architect revisions. ref 202103247161 resubmittal to 202105200733. no underground work. relocate and replace (16) upright sprinklers with new pendent sprinklers on 1/f and basement. | $7,900 |
| Oct 4, 2021 | Never finaled issued Oct 2021, no final | 209 Post St | Aquamatic Fire Protection | 11/f & 12/f: modify (33) fire sprinlers for office t.i. remodel. reroute fire sprinkler piping for new stairs. ref t.i. pa202107124144. maher n/a.Details
11/f & 12/f: modify (33) fire sprinlers for office t.i. remodel. reroute fire sprinkler piping for new stairs. ref t.i. pa202107124144. maher n/a. | $33,400 |
| Aug 23, 2021 | Completed final sign-off Mar 2022 | 600 Townsend St | Aquamatic Fire Protection | ref to t.t. 2019 1210 9087. add/relocted and replace 7 sprinklersr for ti. no underground workDetails
ref to t.t. 2019 1210 9087. add/relocted and replace 7 sprinklersr for ti. no underground work | $4,500 |
| Aug 13, 2021 | Completed final sign-off Nov 2023 | 525 06th St | Aquamatic Fire Protection | add new automatic fire sprinkler system including underground for existing building.Details
add new automatic fire sprinkler system including underground for existing building. | $50,000 |
| Aug 13, 2021 | Completed final sign-off Nov 2023 | 559 06th St | Aquamatic Fire Protection | add new automatic fire sprinkler system including underground for existing building.Details
add new automatic fire sprinkler system including underground for existing building. | $50,000 |
| Aug 9, 2021 | Completed final sign-off Dec 2021 | 2845 18th St | Aquamatic Fire Protection | add 4 new sprinklers for new baths to (e) system.Details
add 4 new sprinklers for new baths to (e) system. | $5,000 |
| Aug 3, 2021 | Completed final sign-off Aug 2022 | 1550 Bryant St | Aquamatic Fire Protection | relocate/replace (108)/add (23)/plug (18) fire sprinklers for t.i. no underground work. ref t.i. bpa#202106162596.Details
relocate/replace (108)/add (23)/plug (18) fire sprinklers for t.i. no underground work. ref t.i. bpa#202106162596. | $22,300 |
| Jul 29, 2021 | Completed final sign-off Sep 2022 | 30 Otis St | Aquamatic Fire Protection | rev to pa# 2021-0715-4440; relocate (29) upright sprinklers with new reliable model-g5 qr concealed pendent sprinlers with black escutcheon plates for new ceiling in lobby & theater.Details
rev to pa# 2021-0715-4440; relocate (29) upright sprinklers with new reliable model-g5 qr concealed pendent sprinlers with black escutcheon plates for new ceiling in lobby & theater. | $6,000 |
| Jul 15, 2021 | Completed final sign-off Sep 2022 | 98 12th St | Aquamatic Fire Protection | fire sprinkler for pa 201912230380. relocate and replace 23 (e) upright sprinklers and add 4 wtih new concealed pendent sprinklers for new ceiling. relocate and replace 26 (e) upright sprinklers with 6 new concealed pendent with black escutcheon plates for new ceilings in lobby and theatre.Details
fire sprinkler for pa 201912230380. relocate and replace 23 (e) upright sprinklers and add 4 wtih new concealed pendent sprinklers for new ceiling. relocate and replace 26 (e) upright sprinklers with 6 new concealed pendent with black escutcheon plates for new ceilings in lobby and theatre. | $25,700 |
| Jun 28, 2021 | Never finaled issued Jul 2021, no final | 2075 Mission St | Aquamatic Fire Protection | relocate 14 pendent heads, add 25 pendents and repl 8 heads for new walls being installed. total 47 heads. repl 70' of 1.5" to 2" pipe. install new 3" and 4" pipes to supply new heads.Details
relocate 14 pendent heads, add 25 pendents and repl 8 heads for new walls being installed. total 47 heads. repl 70' of 1.5" to 2" pipe. install new 3" and 4" pipes to supply new heads. | $16,000 |
| May 20, 2021 | Completed final sign-off Jan 2025 | 1023 Mission St | Aquamatic Fire Protection | relocate and replace (14)/add (13)/plug (18) fire sprinklers for tenant improvement. no underground work. reference t.i. #2020-0324-7162.Details
relocate and replace (14)/add (13)/plug (18) fire sprinklers for tenant improvement. no underground work. reference t.i. #2020-0324-7162. | $10,500 |
| May 20, 2021 | Completed final sign-off Jun 2021 | 449 Castro St | Aquamatic Fire Protection | relocate and replace (1)/add (1)/plug (2) pendent fire sprinklers for tenant improvement. reference t.i. #2020-1109-8556. no underground work.Details
relocate and replace (1)/add (1)/plug (2) pendent fire sprinklers for tenant improvement. reference t.i. #2020-1109-8556. no underground work. | $5,800 |
| May 13, 2021 | Completed final sign-off Aug 2021 | 1532 Harrison St | Aquamatic Fire Protection | as built fire sprinkler plans at projection completion for permit # 2016-0725-3263-s4Details
as built fire sprinkler plans at projection completion for permit # 2016-0725-3263-s4 | $505,300 |
| Apr 13, 2021 | Completed final sign-off Dec 2021 | 99 Missouri St | Aquamatic Fire Protection | the underground fire service is existing, point of connection from the cap 6 inches above finished floor. install a 6" deringer backflow preventer, floor control assembly, main and brnch line piping supplying (122) upright fire sprinklers and (32) concealed pendent fire sprinklers for the new retailDetails
the underground fire service is existing, point of connection from the cap 6 inches above finished floor. install a 6" deringer backflow preventer, floor control assembly, main and brnch line piping supplying (122) upright fire sprinklers and (32) concealed pendent fire sprinklers for the new retail | $77,500 |
| Dec 17, 2020 | Completed final sign-off Mar 2021 | 3701 Noriega St | Aquamatic Fire Protection | install new 8" underground line from meter to flange inside building approimately [15'] of pipe to be install. back flow preventer located inside building.Details
install new 8" underground line from meter to flange inside building approimately [15'] of pipe to be install. back flow preventer located inside building. | $22,500 |
| Nov 19, 2020 | Never finaled issued Dec 2020, no final | 3701 Noriega St | Aquamatic Fire Protection | revision to the fire sprinkler submittal approved under bpa #2019 0315 5294 r2. chages include: (1) removed head from control room, (2) revised backgrounds for the lower basement and roof, (3) removed heads from elevator shafts; (4) moved heads to fix spacing due to backgroundDetails
revision to the fire sprinkler submittal approved under bpa #2019 0315 5294 r2. chages include: (1) removed head from control room, (2) revised backgrounds for the lower basement and roof, (3) removed heads from elevator shafts; (4) moved heads to fix spacing due to background | |
| Sep 26, 2020 | Never finaled issued Oct 2020, no final | 3501 Geary Bl | Aquamatic Fire Protection | as builts for fire permit reference 202007099902Details
as builts for fire permit reference 202007099902 | |
| Jul 9, 2020 | Never finaled issued Jul 2020, no final | 3501 Geary Bl | Aquamatic Fire Protection | f/fs: relocate and replace 9 heads for ti. no undergorund work. ref ti #201807114348 (t-mobile retail)Details
f/fs: relocate and replace 9 heads for ti. no undergorund work. ref ti #201807114348 (t-mobile retail) | $6,900 |
| Jun 12, 2020 | Completed final sign-off Apr 2021 | 3701 Noriega St | Aquamatic Fire Protection | new grocery store: add 32 new pendent heads for all new ceilings. add 13 new dry pendent heads for the new freezers and coolors. add 5 new upright heads for new walls. move 17 (e) upright heads for new walls and lights. ref t.i. 201909181960Details
new grocery store: add 32 new pendent heads for all new ceilings. add 13 new dry pendent heads for the new freezers and coolors. add 5 new upright heads for new walls. move 17 (e) upright heads for new walls and lights. ref t.i. 201909181960 | $37,800 |
| Jun 4, 2020 | Completed final sign-off Jan 2021 | 950 Tennessee St | Thompson Builders Corp | revision to pa# 2017-1201-5291 s3 fire sprinkler addendum.ductile iron piping acceptable for use for underground main piping can have a mechanical joint with mege-lugs in lieu of thrust blocks minimum pipe bury to be 24".Details
revision to pa# 2017-1201-5291 s3 fire sprinkler addendum.ductile iron piping acceptable for use for underground main piping can have a mechanical joint with mege-lugs in lieu of thrust blocks minimum pipe bury to be 24". | $3,000 |
| Nov 27, 2019 | Completed final sign-off Feb 2020 | 777 Tennessee St | Aquamatic Fire Protection | asbuilt to previously aproved ug/oh fire sprinkler system. revision consist of removing car stacker and sprinklers that were installed there. ref pa 2019-0813-8616Details
asbuilt to previously aproved ug/oh fire sprinkler system. revision consist of removing car stacker and sprinklers that were installed there. ref pa 2019-0813-8616 | |
| Aug 13, 2019 | Completed final sign-off Feb 2020 | 777 Tennessee St | Aquamatic Fire Protection | revision to app#201507141485 (s4) ug/oh fire sprinkler system. revision consists of 3 foot change in fire service lateral location. n/a for maherDetails
revision to app#201507141485 (s4) ug/oh fire sprinkler system. revision consists of 3 foot change in fire service lateral location. n/a for maher | |
| Aug 1, 2019 | Completed final sign-off Oct 2020 | 1830 17th St | Aquamatic Fire Protection | revised the lower level fire sprinkler design from previously approved submittal appln #201904036951Details
revised the lower level fire sprinkler design from previously approved submittal appln #201904036951 | |
| Jul 31, 2019 | Completed final sign-off Nov 2019 | 180 Townsend St | Aquamatic Fire Protection | add 2 plugs for 2 fire sprinklers. add branch line restraints. no underground work. ref pa 2019-0211-2601Details
add 2 plugs for 2 fire sprinklers. add branch line restraints. no underground work. ref pa 2019-0211-2601 | $7,000 |
| Jul 15, 2019 | Completed final sign-off Feb 2020 | 1300 Bryant St | Aquamatic Fire Protection | (42) add relocate and plug ssps for altered walls and ceilings. ref pa 2019-0603-2303Details
(42) add relocate and plug ssps for altered walls and ceilings. ref pa 2019-0603-2303 | $14,000 |
| Jun 26, 2019 | Completed final sign-off Aug 2019 | 445 Geary St | Aquamatic Fire Protection | fire sprinkler: add (3) new pendent fire sprinklers, plug 4 pendent fire sprinklers. add branch line restraints in area of work. ref ti #201906062705. no underground work.Details
fire sprinkler: add (3) new pendent fire sprinklers, plug 4 pendent fire sprinklers. add branch line restraints in area of work. ref ti #201906062705. no underground work. | $7,300 |
| Apr 3, 2019 | Never finaled issued Jun 2019, no final | 1830 17th St | Aquamatic Fire Protection | install new overhead sprinkler system. begin @ (e) underground. modify existing. stubbed into riser room. install new back flow preventer. reconnect the wall mounted fdc. install new riser control assembly supplying new overhead wet pipe fire sprinkler system for 2 story building. 99 heads.Details
install new overhead sprinkler system. begin @ (e) underground. modify existing. stubbed into riser room. install new back flow preventer. reconnect the wall mounted fdc. install new riser control assembly supplying new overhead wet pipe fire sprinkler system for 2 story building. 99 heads. | $59,900 |
| Mar 15, 2019 | Completed final sign-off Apr 2021 | 3701 Noriega St | Aquamatic Fire Protection | (n) sprinkler & standpipe system for (n) 4-story retail/residential building. (2) levels of basement with parking, (1) floor of retail (future) and (3) floors of residential.Details
(n) sprinkler & standpipe system for (n) 4-story retail/residential building. (2) levels of basement with parking, (1) floor of retail (future) and (3) floors of residential. | $215,000 |
| Mar 7, 2019 | Completed final sign-off Mar 2019 | 3241 16th St | Aquamatic Fire Protection | relocate and replace 2 pendent fire sprinlkers. no underground work ref 201901170564Details
relocate and replace 2 pendent fire sprinlkers. no underground work ref 201901170564 | $6,500 |
| Jan 30, 2019 | Completed final sign-off Apr 2019 | 140 South Park | Aquamatic Fire Protection | 1/f: modify 8 relocates , 1 add, and 1 plug fire sprinkers for tenant improvement ref 201901180789. no underground work.Details
1/f: modify 8 relocates , 1 add, and 1 plug fire sprinkers for tenant improvement ref 201901180789. no underground work. | $5,900 |
| Jan 30, 2019 | Never finaled issued Jan 2019, no final | 605 20th St | Aquamatic Fire Protection | 1/f:demo 25 pendent fire sprinklers and supply piping ref 201812319395. no underground work.Details
1/f:demo 25 pendent fire sprinklers and supply piping ref 201812319395. no underground work. | $6,800 |
| Oct 25, 2018 | Completed final sign-off Jan 2019 | 100 Church St | Aquamatic Fire Protection | relocate and replace exiting fire sprinklers with new fire sprinklers for new walls and ceilings. ref t.i. pa201807124452. maher n/a.Details
relocate and replace exiting fire sprinklers with new fire sprinklers for new walls and ceilings. ref t.i. pa201807124452. maher n/a. | $16,000 |
| Oct 11, 2018 | Completed final sign-off Feb 2019 | 2633 Ocean Av | Aquamatic Fire Protection | modify 2nd fl sprinkler system for tenant improvement. no underground work. ref ti #201808167489.Details
modify 2nd fl sprinkler system for tenant improvement. no underground work. ref ti #201808167489. | $14,600 |
| Oct 9, 2018 | Completed final sign-off Apr 2019 | 559 Clay St | Aquamatic Fire Protection | 3rd & 4th flrs - revise (e) fire sprinkler system for ti. no underground workDetails
3rd & 4th flrs - revise (e) fire sprinkler system for ti. no underground work | $29,000 |
| Dec 27, 2017 | Completed final sign-off Jan 2018 | 394 Pacific Av | Aquamatic Fire Protection | 4th floor: as built for fire sprinkler t.i. per app#201703312893. n/a for maherDetails
4th floor: as built for fire sprinkler t.i. per app#201703312893. n/a for maher | |
| Dec 1, 2017 | Completed final sign-off Mar 2021 | 950 Tennessee St | Thompson Builders Corp, Aquamatic Fire Protection | to erect new 4 stories, 1 basement, type i-b, 100 units residential and parking bldg. (r-2,s-2) ** maher: n/a **Details
to erect new 4 stories, 1 basement, type i-b, 100 units residential and parking bldg. (r-2,s-2) ** maher: n/a ** | $35,000,000 |
| Sep 7, 2017 | Never finaled issued Sep 2017, no final | 386 Geary St | Aquamatic Fire Protection | relocate & replace (17) pendent sprinklers. upgrade bracing for mains & branch lines. no underground work. ref pa #201308073760Details
relocate & replace (17) pendent sprinklers. upgrade bracing for mains & branch lines. no underground work. ref pa #201308073760 | $1,600 |
| Sep 7, 2017 | Never finaled issued Sep 2017, no final | 584 Hayes St | Aquamatic Fire Protection | as builts - reference #201706139198. fire sprinklers onlyDetails
as builts - reference #201706139198. fire sprinklers only | |
| Sep 7, 2017 | Completed final sign-off Sep 2017 | 935 North Point St | Aquamatic Fire Protection | as-built - reference t.i. #201505015172. fire sprinklers onlyDetails
as-built - reference t.i. #201505015172. fire sprinklers only | |
| Jul 31, 2017 | Completed final sign-off Aug 2017 | 850 Folsom St | Aquamatic Fire Protection | 1st fl: relocate and replace (1) pendent fire sprinkler, install branch line restraint on branch line worked on. no underground work. ref. to pa#2017-0519-7092. n/a ordinance #155-13Details
1st fl: relocate and replace (1) pendent fire sprinkler, install branch line restraint on branch line worked on. no underground work. ref. to pa#2017-0519-7092. n/a ordinance #155-13 | $2,500 |
| Jul 11, 2017 | Completed final sign-off Jul 2017 | 140 Maiden Ln | Aquamatic Fire Protection | replace (10) pendent fire sprinklers. no under gorund work. ref pa #201705257702.Details
replace (10) pendent fire sprinklers. no under gorund work. ref pa #201705257702. | $5,100 |
| Jun 13, 2017 | Completed final sign-off Jun 2018 | 584 Hayes St | Aquamatic Fire Protection | on 1st floor - relocate & replace 14 pendent fire sprinklers, relocate 2 upright fire sprinklers and 1 pendent fire sprinkler and plug 1 pendent fire sprinkler - no underground work. ref pa 2017-0316-1605Details
on 1st floor - relocate & replace 14 pendent fire sprinklers, relocate 2 upright fire sprinklers and 1 pendent fire sprinkler and plug 1 pendent fire sprinkler - no underground work. ref pa 2017-0316-1605 | $6,100 |
| May 12, 2017 | Never finaled issued May 2017, no final | 180 Capp St | Aquamatic Fire Protection | replace 156 upright sprinklers and 9 pendnent sprinklers due to old sprinklers. upgrade eqrthquake bracing, and branch line restraints. no underground work. deficiency work only - no ti to referenceDetails
replace 156 upright sprinklers and 9 pendnent sprinklers due to old sprinklers. upgrade eqrthquake bracing, and branch line restraints. no underground work. deficiency work only - no ti to reference | $16,000 |
| Mar 31, 2017 | Completed final sign-off Jan 2018 | 394 Pacific Av | Aquamatic Fire Protection | 4th flr: ti- relocate and replace 2 ssp. relocate and replace 4 ssu add 3 ssu. install earthquake bracing branchline restraints in area of work. no underground work ref t- 201701237655 maher naDetails
4th flr: ti- relocate and replace 2 ssp. relocate and replace 4 ssu add 3 ssu. install earthquake bracing branchline restraints in area of work. no underground work ref t- 201701237655 maher na | $9,700 |
| Feb 6, 2017 | Completed final sign-off May 2017 | 1275 Minnesota St | Aquamatic Fire Protection | fire sprinkler for ti 201609066847 - 7 new sprinklers maher naDetails
fire sprinkler for ti 201609066847 - 7 new sprinklers maher na | $2,400 |
| Dec 28, 2016 | Completed final sign-off Jan 2017 | 450 Hayes St | Aquamatic Fire Protection | 1st floor - relocate (4) uprights for new full height walls at open ceilings & (1) concealed pendent at new suspended gypsum board ceiling. ref pa #201610059630.Details
1st floor - relocate (4) uprights for new full height walls at open ceilings & (1) concealed pendent at new suspended gypsum board ceiling. ref pa #201610059630. | $4,900 |
| Sep 22, 2016 | Completed final sign-off Oct 2016 | 711 Van Ness Av | Aquamatic Fire Protection | #320- relocate and replace (18) pendent sprinklers, add (2), plug (3) pendent sprinklers, add branch line restraints in area of work only, no underground work. ref. t.i. pa#2016-0811-4817Details
#320- relocate and replace (18) pendent sprinklers, add (2), plug (3) pendent sprinklers, add branch line restraints in area of work only, no underground work. ref. t.i. pa#2016-0811-4817 | $5,700 |